Technical study

Where the Energy Goes in Green Hydrogen Production — and Where Optimisation Pays

Technical report for green hydrogen and energy optimisation service

Scope
Water-electrolysis plants (alkaline, PEM and solid oxide), from the electricity import meter to hydrogen storage
Prepared
October 2026
Basis
Published research, technical literature and engineering synthesis
Contents

Executive summary

Splitting liquid water needs at least 1.23 V of electrical work at standard conditions; voltage above the 1.48 V thermoneutral value is released as heat. By Faraday’s law, stack consumption ≈ 26.6 × Vcell ÷ ηF kWh/kg (ηF: faradaic efficiency), so each 0.1 V per cell costs about 2.7 kWh/kg.

US DOE status figures for 2022 put alkaline and PEM stacks at 1.9 V per cell and 51 kWh/kg, and complete systems at 55 kWh/kg, or 61% on a lower-heating-value basis [2, 3]; the stack therefore accounts for most of the loss. Published 2020 system ranges are much wider, 50–83 kWh/kg [1], partly reflecting different boundaries and operating points.

Electricity is the largest single cost of on-site green hydrogen, but investment cost dominates at low operating hours [1]. Efficiency and utilisation must therefore be optimised together and, in the UK, alongside carbon intensity calculated per 30-minute reporting unit [12].

StageMechanismImpactOptimisation lever
Power conversion (transformer, rectifier)AC/DC losses; harmonics and low power factor at low load [8]Specified efficiency >94% now, >98% in future [8]; very low at low load [1]Topology matched to duty; staged rectifier–stack modules
Electrolysis stackVoltage above 1.48 V becomes heat; crossover lowers faradaic efficiencyLargest loss; stack uses 51 of 55 kWh/kg at 2022 status [2, 3]Current density; temperature control; stack upgrades
Part load and standbyFixed loads, supply losses and gas impurity grow relative to outputAlkaline part-load range limited by gas impurity [6]Minimum-load and standby policy; staging; buffering
Degradation over lifeVoltage rises at constant current4.8 (PEM) and 3.2 (alkaline) mV/kh at 2022 status; end of life at 10% voltage rise [2, 3]Voltage trending; water quality; replacement timing
Balance of plantWater treatment, cooling, deoxidation and dryingWater purification <USD 0.01/kg [1]; heat ≈20–30% of stack input over life in one PEM case [9]Variable-speed cooling; heat recovery; purity matched to use
CompressionRaising pressure for storage or transport1→30 bar ≈3.5–4% of LHV [1]Pressurised output; staging; matched turndown
Storage and deliveryFurther compression, liquefaction, leakageLiquefaction 10–13 kWh/kg in practice [4]Storage form matched to end use; leak detection
Table 1. Where energy is used or lost, from meter to storage

Source: engineering synthesis from [1]–[4], [6], [8], [9]. Values indicate magnitude under the cited conditions, not guarantees.

Conclusions at a glance

  • Stack voltage the dominant loss; compare cell voltage at stated current density, temperature and age.
  • Outside the stack conversion and auxiliary losses are modest at rated load but grow at low load.
  • Utilisation at low operating hours the capital charge dominates; small efficiency gains rarely justify lost hours.
  • Degradation and compression manage degradation through replacement timing; pressurised output avoids the low-pressure stages, which cost the most energy per bar.
  • Heat and carbon heat pays only where demand is close and coincident; lower kWh/kg widens the carbon-compliance margin.

1 Energy basis and KPIs

1.1 Reference values

Basic thermodynamics gives four reference points:

  • Reversible voltage, 1.23 V (25 °C, 1 bar): the minimum electrical work, ≈32.7 kWh/kg.
  • Thermoneutral voltage, ≈1.48 V for liquid water: the reaction enthalpy, equal to the higher heating value (HHV); about 1.29 V for steam [7].
  • Heating values: lower heating value (LHV) ≈33.3 kWh/kg (≈120 MJ/kg); HHV ≈39.4 kWh/kg (≈142 MJ/kg).
  • Faraday’s law: ≈26.6 kAh of charge per kilogram of H₂.

At 1.9 V and full faradaic efficiency, stack consumption is about 50.5 kWh/kg, consistent with DOE’s 51 kWh/kg, which includes a crossover allowance [2]. About 22% of that input, (1.9 − 1.48) ÷ 1.9, becomes heat for the cooling system.

1.2 Stack versus system; LHV versus HHV

Stack specific energy consumption (SEC) divides DC stack energy by hydrogen produced; system SEC divides AC import energy, including conversion and auxiliaries, by hydrogen delivered at stated purity and pressure. Efficiency is heating value ÷ SEC: 55 kWh/kg is 61% on an LHV basis [2] but about 72% on an HHV basis. The UK government’s 2021 cost study assumed 2020 whole-plant efficiencies of 77% (alkaline) and 72% (PEM) on an HHV basis, excluding compression [11], roughly 51 and 55 kWh/kg. Guarantees should state boundary, basis, pressure, purity, load point, averaging period and stack age.

1.3 KPIs and failure signatures

KPIPrimary indicatorsFailure signature
Stack SEC (DC)Cell and stack voltage at reference current density and temperatureVoltage rising at constant conditions; cell spread widening
System SEC (AC)Import kWh/kg at stated purity and pressure, by load bandGap to stack SEC widening at part load
Faradaic efficiencyMeasured ÷ theoretical H₂ from DC currentFalling at low load or high pressure; rising H₂-in-O₂
Power conversionEfficiency, power factor, harmonics, rippleDeterioration at low load
Auxiliaries and standbySub-metered kWh/kg; kWh per standby hourFixed loads dominating at low output
DegradationmV/kh at reference conditionsRate accelerating after duty or water-quality changes

Source: synthesis from [1]–[3], [6], [8]; align definitions with OEM guarantee terms.

2 Electrolyser technologies and their energy characteristics

CharacteristicAlkalinePEMSolid oxide
Operating temperature [1]70–90 °C50–80 °C700–850 °C
System SEC, 2020 range [1]50–78 kWh/kg50–83 kWh/kg45–55 kWh/kg
2022 status: current density at 1.9 V; stack/system SEC [2, 3]0.5 A/cm²; 51/55 kWh/kg2.0 A/cm²; 51/55 kWh/kgNot covered
Stack lifetime, 2020 [1]60,000 h50,000–80,000 h<20,000 h
Dynamic behaviourPart-load range limited by gas impurity [6]Preferred for dynamic duty: short start-up, broad load range [6]Fast ramping when hot; limited thermal cycles [7]
Table 2. Energy-relevant characteristics by technology

Source: [1]–[3], [6], [7]. Values differ in date, scale and boundary; they are not like-for-like.

PEM matches alkaline consumption at four times the current density [2, 3], needing less active area but iridium-bearing anodes [2]. PEM can run at differential pressure, typically 30–70 bar [1], reducing compression, though higher pressure increases hydrogen permeation [1]; alkaline gas impurity also rises with pressure [6]. Solid oxide electrolysers (SOEC) need less electricity because part of the energy arrives as heat in the steam: systems should operate near the thermoneutral potential, and heat from exothermic downstream synthesis can raise the steam [7]. Heat should be counted as an input with its own cost and carbon intensity. Most reported SOEC stack tests now show degradation below 1% per 1,000 h [7], against 0.25% for DOE’s 2022 PEM status [2].

3 Power supply and operating strategy with variable renewable electricity

3.1 Capacity factor versus cost

The levelised cost of hydrogen (LCOH) has two dominant terms: electricity cost per kilogram (SEC × price) and the capital charge per kilogram (annualised capital and fixed costs ÷ output). IRENA notes that investment cost dominates at low operating hours, electricity dominates as hours increase, and about 3,000–4,000 hours per year may achieve the largest reduction in the investment contribution [1]. In the UK government’s 2021 study, cutting load factor to 15% raised LCOH more than raising it to 35% lowered it, and free curtailed electricity at around 25% load factor left fixed costs dominant [11]. Sizing and real-time dispatch against prices and renewable output are therefore central design variables [10].

3.2 Ramping, minimum load and standby

At lower current density, cell voltage falls and stack efficiency improves, yet system SEC can worsen: power-supply losses become large at low load [1], fixed auxiliary loads are spread over less hydrogen, and gas crossover continues while production falls. In alkaline systems, impurity rises at low current density, with emergency-shutdown limits at 2 vol% hydrogen in oxygen [6], which sets the practical minimum load. The turning point is plant-specific and must be measured.

Hot SOEC stacks can ramp from zero to 80% load within milliseconds, but ceramic-supported stacks tolerate only about 150 thermal cycles [7]; balance of plant such as compressors, rather than the stack, often limits flexibility [1]. Load range, load gradients, start-up time and standby losses should be specified explicitly [5], and hot or cold standby chosen from measured standby energy and idle durations.

3.3 Buffering with batteries or hydrogen storage

A battery can bridge short dips, holding the electrolyser above minimum load, but adds capital cost and round-trip losses and cannot cover long lulls. Hydrogen storage decouples production from offtake, letting the electrolyser follow cheap or low-carbon electricity, at the cost of compression energy and storage capital. Dispatch modelling with measured profiles should decide between them [10].

3.4 Power quality

Thyristor rectifiers at large firing angles, typical of low-power operation, produce more harmonics and a lower power factor [8]. Converter requirements tabulated by Chen et al. include efficiency above 94%, power factor above 0.90 and current distortion below 5%, with future targets of 98%, 0.99 and ripple of 5% or less [8]; high ripple lowers efficiency [6]. Staged rectifier–stack modules can outperform one large unit at deep turndown.

4 Balance of plant and compression

4.1 Water, cooling, purification and drying

Stoichiometry requires 9 kg of water per kilogram of hydrogen; with demineralisation and process inefficiencies, consumption is typically 18–24 kg/kg, and purification costs less than USD 0.01/kg of hydrogen [1]. Water quality matters for reliability rather than energy, because impurities have a major impact on stack lifetime [1].

Cooling must remove the stack input not stored as chemical energy, about 20% at start of life and about 30% after ten years in one modelled PEM case [9], so degradation also raises cooling loads. Deoxidation, purging and dryer-regeneration losses are design-specific; vendor figures should be verified in operation.

4.2 Compression

For an ideal gas compressed isothermally, work scales with ln(p₂/p₁): compressing from 1 to 30 bar takes the same ideal work as from 30 to 900 bar. Delivering hydrogen at pressure therefore removes the most expensive compression per bar.

DutyBasisEnergy
1 → 30 barEstimate for atmospheric alkaline output [1]≈3.5–4% of LHV (≈1.2–1.3 kWh/kg)
20 → 350 barTheoretical isothermal [4]1.05 kWh/kg
20 → 700 barTheoretical isothermal [4]≈1.36 kWh/kg (≈4% of LHV)
To 350 barMeasured at on-site-production refuelling stations [4]1.7–6.4 kWh/kg; 2–4 kWh/kg excluding outliers
LiquefactionOperating plants [4]10–13 kWh/kg (30–40% of LHV)
Table 3. Indicative energy for compression and liquefaction

Source: [1], [4]. Station data were compiled in 2009 from refuelling-scale equipment.

IRENA estimates a compressor of about 4 MW for a 100 MW atmospheric electrolyser delivering 30 bar [1]. Because recycle and bypass waste energy when output varies, compressor turndown and buffer volume should match the electrolyser profile.

5 Heat recovery and site integration

TechnologyHeat levelPlausible site usesConstraint
AlkalineBelow the 70–90 °C operating range [1]Space and district heating; process and feed-water preheatLow grade; heat pump for higher temperatures
PEMBelow the 50–80 °C operating range [1]; 54 °C delivered in one modelled case [9]Low-temperature heating networks; washing; preheatingValue falls sharply with upgrading or distance [9]
Solid oxide700–850 °C operation [1]Net heat consumer: steam from exothermic synthesis [7]Heat import, not export, is the question
Table 4. Recoverable heat by technology

Source: [1], [7], [9]; site uses are engineering inference.

In a modelled 2.5 MW PEM installation, 14–15% of stack electricity could be used by a heat consumer, raising average ten-year efficiency from 76% to 90% (HHV) [9]. Using a heat pump to reach 100 °C roughly quadrupled the heat’s levelised cost, heat transport was feasible only over about 1–3 km depending on use case, and even with buffering not all heat could be used [9]. Recovery pays where low-temperature demand is close, coincident and otherwise met by purchased energy. Oxygen, about 8 kg per kilogram of hydrogen, is a further by-product to evaluate.

6 Techno-economics: levelised cost of hydrogen drivers

In simplified form, LCOH ≈ (annualised capital + fixed O&M) ÷ output + SEC × electricity price + stack replacement − by-product credits. Installed electrolysis capacity doubled in 2025 to surpass 4 GW, yet the IEA expects fossil-based production to remain less costly than renewable hydrogen in most regions in the near term [13]. IRENA notes that a power cost translates into roughly 1.5 times that value in hydrogen production cost [1].

DriverHow it enters LCOHSensitivity and evidence
Electricity priceSEC × priceLargest single component [1]; UK price sensitivities moved LCOH by up to £22/MWh (HHV) for a 2030 plant [11]
UtilisationCapital and fixed costs ÷ outputInvestment dominates at low hours [1]; response to load factor is asymmetric [11]
System SECMultiplies electricity costAt 55 kWh/kg, each 1 kWh/kg is ≈1.8% of consumption [2]
Capital and stack replacementAnnualised capital; periodic stacks2021 UK assumptions: stacks 50–60% of plant capital, replaced every 7–11 years [11]
Heat and oxygenBy-product creditsSite-specific [9]
Table 5. Principal LCOH drivers and sensitivities

Efficiency projects should therefore be valued at the electricity price in the hours the plant runs.

7 Carbon intensity and standards

The UK Low Carbon Hydrogen Standard (LCHS), published by the Department for Energy Security and Net Zero, sets a method for calculating hydrogen-production emissions and a threshold for hydrogen to count as low carbon [12]. Version 4 (January 2026) is used to assess eligibility under the Hydrogen Production Revenue Support (Directions, Eligibility and Counterparty) Regulations 2023; supported projects follow the version named in their agreement [12]. For electrolytic hydrogen:

  • Threshold: no more than 20 gCO₂e/MJ of hydrogen product, LHV basis [12].
  • Boundary: “point of production”, covering Scope 1, Scope 2 and partial Scope 3 emissions, including compression and purification to the Standard’s minimum pressure and purity, and input materials such as water [12].
  • Time resolution: emissions are allocated to consignments within 30-minute reporting units, optionally aggregated monthly into weighted-average consignments [12].
  • Electricity: generators supplying through eligible PPAs must show temporal correlation in each reporting unit; other grid electricity uses delivered intensities from the Data Annex, with a separate intensity for curtailment evidenced by a Bid Offer Acceptance [12].
  • Other conditions: an eligible pathway, monthly reporting, a fugitive hydrogen emissions risk reduction plan and annual report, and a data collection and monitoring procedure [12].

As arithmetic only, 20 gCO₂e/MJ × ≈120 MJ/kg ≈ 2.4 kgCO₂e/kg. At 55 kWh/kg [2], electricity averaging about 44 gCO₂e/kWh would use the entire allowance; at 50 kWh/kg, about 48 g/kWh. This is not a compliance calculation, but it shows why efficiency, utilisation and half-hourly timing are coupled.

8 Optimisation and monitoring programme

8.1 Minimum data package

CategoryMeasurementsDecision supported
ElectricalAC import; rectifier input and output; stack DC current and voltage; power qualityConversion losses; module staging
StackCell or cell-group voltages; temperatures; pressures; hours and startsVoltage efficiency; degradation
GasH₂ mass flow; purity; O₂-in-H₂ and H₂-in-O₂; dew pointFaradaic efficiency; minimum load; purification loss
Auxiliaries and compressionSub-metered cooling, water, purification, drying, HVAC and compressor energyFixed-load reduction; compression SEC
Water and heatWater flow and conductivity; heat rejected and recoveredWater quality; heat integration
Commercial and carbonHalf-hourly prices and grid intensity; PPA generation dataDispatch; LCHS consignment results

Agree metering accuracy and sampling with the OEM and any scheme’s monitoring procedure.

8.2 Study sequence

  1. Boundary and metering audit: close the energy balance from import meter to storage.
  2. Baseline: system SEC–load curve including standby; stack voltage–current curve at reference temperature.
  3. Classify the limiting loss: stack voltage, part load and standby, conversion, auxiliaries, compression or utilisation.
  4. Model operating strategy and by-product use with measured price, generation and demand profiles.
  5. Trial changes one at a time, then confirm.

8.3 Acceptance criteria

Trial phaseControlled changeAcceptance criteria
A. BaselineNone; establish variabilityEnergy and mass balances close within an agreed tolerance
B. Operating set-pointsMinimum load, standby or staging within the OEM envelopeLower normalised system kWh/kg without purity, trip or degradation penalty
C. EquipmentRectifier, auxiliary, heat-recovery or compressor changeNormalised saving matches the business case; no availability loss
D. ConfirmationRepeat best condition or return to baselineImprovement reproducible beyond baseline variation; carbon result compliant

Changes require management-of-change and process-safety review.

9 Trade-offs

Control knobPotential benefitPrincipal trade-off
Current densityLower cell voltage and stack SECMore capital per kilogram
Output pressureLess downstream compressionHigher crossover and gas impurity [1, 6]
Minimum-load set-pointMore hours on variable supplyGas-purity margin; part-load efficiency [6]
Hot versus cold standbyFast restart versus no standby energyEnergy without output versus thermal cycling
Battery bufferFewer trips; minimum load maintainedCapital cost; round-trip losses
Hydrogen storageProduction decoupled from offtakeCompression energy; storage capital
Electrolyser-to-supply sizingHigher utilisation or more low-cost power usedCapital per kilogram versus unused supply [10]
Stack replacement timingRestores voltage efficiencyReplacement capital and downtime
Heat recoveryBy-product value; site fuel savingsPipework, heat pumps, intermittency [9]

10 Conclusions

In alkaline and PEM plants, stack voltage governs most of the energy that does not become hydrogen. Losses outside the stack rise at low load, where plants on variable supply can spend much of their time, and degradation slowly raises kWh/kg and cooling duty. Because electricity price and utilisation dominate levelised cost, efficiency measures should be judged on cost and carbon together in the hours the plant actually runs.

References

  • [1] IRENA. Green Hydrogen Cost Reduction: Scaling up Electrolysers to Meet the 1.5 °C Climate Goal. International Renewable Energy Agency, Abu Dhabi, 2020. ISBN 978-92-9260-295-6. Report
  • [2] U.S. Department of Energy. “Technical Targets for Proton Exchange Membrane Electrolysis.” Web page, published 22 December 2015, last modified 29 May 2026; accessed 21 October 2026. Source link
  • [3] U.S. Department of Energy. “Technical Targets for Liquid Alkaline Electrolysis.” Web page, published 15 March 2023, last modified 29 May 2026; accessed 21 October 2026. Source link
  • [4] Gardiner, M. “Energy Requirements for Hydrogen Gas Compression and Liquefaction as Related to Vehicle Storage Needs.” DOE Hydrogen and Fuel Cells Program Record 9013, 7 July 2009. Record
  • [5] Buttler, A.; Spliethoff, H. “Current Status of Water Electrolysis for Energy Storage, Grid Balancing and Sector Coupling via Power-to-Gas and Power-to-Liquids: A Review.” Renewable and Sustainable Energy Reviews 82 (2018): 2440–2454. DOI
  • [6] Brauns, J.; Turek, T. “Alkaline Water Electrolysis Powered by Renewable Energy: A Review.” Processes 8 (2020): 248. DOI
  • [7] Hauch, A.; Küngas, R.; Blennow, P.; Hansen, A. B.; Hansen, J. B.; Mathiesen, B. V.; Mogensen, M. B. “Recent Advances in Solid Oxide Cell Technology for Electrolysis.” Science 370 (2020): eaba6118. DOI
  • [8] Chen, M.; Chou, S.-F.; Blaabjerg, F.; Davari, P. “Overview of Power Electronic Converter Topologies Enabling Large-Scale Hydrogen Production via Water Electrolysis.” Applied Sciences 12 (2022): 1906. DOI
  • [9] van der Roest, E.; Bol, R.; Fens, T.; van Wijk, A. “Utilisation of Waste Heat from PEM Electrolysers – Unlocking Local Optimisation.” International Journal of Hydrogen Energy 48 (2023): 27872–27891. DOI
  • [10] Glenk, G.; Reichelstein, S. “Economics of Converting Renewable Power to Hydrogen.” Nature Energy 4 (2019): 216–222. DOI
  • [11] Department for Business, Energy & Industrial Strategy. Hydrogen Production Costs 2021. GOV.UK, August 2021. Report
  • [12] Department for Energy Security and Net Zero. UK Low Carbon Hydrogen Standard, version 4. GOV.UK, January 2026; accessed 21 October 2026. Source link
  • [13] International Energy Agency. Global Hydrogen Review 2026. IEA, Paris, June 2026. Licence: CC BY 4.0. Report

Exploring green hydrogen or looking to cut energy costs?

Tell us about your site and goals.

info@xlenergy.co.uk